HV Transformer
Jump to navigation
Jump to search
| HV Transformer | |
|---|---|
| Properties | |
| Type | Transformer |
| Tool |
|
| Stackable | Yes (64)
|
| Energy Consumption | |
| Max EU Input | 2147483647 EU/t (??) |
| Technical Details | |
| UU Cost | {{{uu_cost}}} |
| First appearance | ? |
| ID | IC2:{{{id}}} |
|
| |
A HV Transformer is used to limit energy flow to 512 EU/t.
Transformers have two modes - step-up and step-down. By default, a transformer will operate in step-down mode unless it receives a redstone signal. This can be changed in the GUI.
In step-down mode, an HV transformer will accept up to 2048 EU/t to the 5-dot face without exploding, and output 512 EU/t from the 1-dot faces. Step-up mode appears to be useless.
Converting to HV[edit]
In order to convert to HV, you must point the input cable to the 5-dotted side and then link any number of output cables from the 1-dotted sides.
Latest Recipe[edit]
Energy[edit]
| EU | |
|---|---|
| Input | 2048 EU/t |
| Output | Variable
|
| Storage | 2048 |
History (IC²)[edit]
| IC² | Minecraft | Change |
|---|---|---|
| Industrial Craft² | ||
| 1.97 | 1.2.5 | Before this version of IC², the HV Transformer was crafted using this recipe: |
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||