Difference between revisions of "Tutorial:Wiring"

From Industrial-Craft-Wiki
Jump to navigation Jump to search
(Major update of the top of the tutorial)
Line 10: Line 10:


insert a pic of improper and proper placement of wires here
insert a pic of improper and proper placement of wires here
COMPLETED THE PHOTO just need to upload


Machines will accept power input from '''all 6 sides'''.
Machines will accept power input from '''all 6 sides'''.
Line 21: Line 22:




Starting simple this is the most basic set up without omitting the [[BatBox]]. The max [[Cable|insulated cable]] length is achieved here. The '''cable is <span style="color:#0066FF">5</span> blocks long'''. <span style="color:#0066FF">'''You lose [[EU]] if the current in the cable travels for too long, losing 1 [[EU]] upon reaching the 6th block, then another 1 [[EU]] for every 5 blocks after that.'''</span>
Starting simple this is the most basic set up without omitting a [[BatBox]]. The max [[Cable|insulated cable]] length is achieved here. The '''cable is <span style="color:#0066FF">4</span> blocks long'''. <span style="color:#0066FF">'''You lose [[EU]] if the current in the cable travels for too long, losing 1 [[EU]] upon reaching the 5th block, then another 1 [[EU]] for every 5 blocks after that.'''</span>


[[file:wiring_3.png|link=]]
[[file:wiring_3.png|link=]]
Line 36: Line 37:




This is a simple 2x solar flower setup with a loop. This will enable you to spread [[EU]] around your Factory and not have it bottleneck in any particular spot. Take note the '''BatBox connecting the generators''' and the loop is '''set @ 32 [[EU]]s'''
This is a simple 2x solar flower setup with a loop. This will enable you to spread [[EU]] around your Factory and not have it bottleneck in any particular spot. Take note the '''BatBox connecting the generators to the loop.
that way the [[EU]] will be evenly distributed around the area. In the center of the solar flower there is a wire, a normal,average wire.(because of advances in the programing of the wires they now allow to be connected upto 6 sides simultaneously opposed to the 3 side max in IC.)
that way the [[EU]] will be evenly distributed around the area. In the center of the solar flower there is a wire, a normal,average wire.(because of advances in the programing of the wires they now allow to be connected upto 6 sides simultaneously opposed to the 3 side max in IC.)


Line 52: Line 53:




this caused a '''loop of power to be sent from the top of the HVT back into the MFE hence killing the setup.'''
this caused a '''loop of power to be sent from the top of the MFE(output) back into the batBox hence killing the setup.(and wasting the wire because it couldnt handle the power and just melted)
 
To properly use a MFE, you need to use a [[LV_Transformer|Low Voltage Transformer. the MFE is used to scale the voltage up and the [[LV_Transformer|Low voltage transformer]] to scale it back down. Quite similar to real life and your local power grid.doing this increases the range of the power but needs a better [[Cable]]. The energy loss is less because you are sending less packets that are larger, they '''still lose [[EU]] over the cable but you lose less'''.  
To properly use HVT you need to use them in pairs. One to scale the voltage up and one to scale it back down. Quite similar to real life and your local power grid. Then you can place up to <span style="color:#0066FF">9+(1999x3)</span> pieces of cable and still get 1 [[EU]] at the other end, this will waste 1999 [[EU]] in the precess though so try to '''keep the cable length under <span style="color:#0066FF">150</span>'''. so in short the inputs are on the side of the '''HVT(can accept 4 inputs at once) and the output is TOP (2000 [[EU]]) and bottom (50 [[EU]])'''. The energy loss is less because you are sending less packets that are larger, they '''still lose [[EU]] over the cable but you lose less'''.  


[[file:wiring_9.png|link=]]
[[file:wiring_9.png|link=]]

Revision as of 04:25, 23 October 2011

Special Thanks To: Kingy24!

updated to v6.80 by Talonius Please note this tutorial was made for IC1 and is largely out of date for IC2

Warning!!! This tutorial is under a update to IC2 and may contain incorrect info until it is finished(and even then their may be a mistake(hey I'm not perfect but i don't see you doing it!))


First, Cables do not act like Redstone, you can not place them diagonally to travel in a stair formation. They must be placed orthogonally.

insert a pic of improper and proper placement of wires here COMPLETED THE PHOTO just need to upload

Machines will accept power input from all 6 sides.

Wiring 1.png


Generators will output power from all 6 sides (but only from one side at any one time), however don't cover the top of a Solar Panel for obvious reasons.

Wiring 2.png


Starting simple this is the most basic set up without omitting a BatBox. The max insulated cable length is achieved here. The cable is 4 blocks long. You lose EU if the current in the cable travels for too long, losing 1 EU upon reaching the 5th block, then another 1 EU for every 5 blocks after that.

Wiring 3.png


This setup will not work as the BatBox is not a splitter, it will accept input from 5 sides at the same time but will only output on the output face marked with dot.

Wiring 4.png


This is a simple buffer, it can be used to store EU

Wiring 5.png


This is a simple 2x solar flower setup with a loop. This will enable you to spread EU around your Factory and not have it bottleneck in any particular spot. Take note the BatBox connecting the generators to the loop. that way the EU will be evenly distributed around the area. In the center of the solar flower there is a wire, a normal,average wire.(because of advances in the programing of the wires they now allow to be connected upto 6 sides simultaneously opposed to the 3 side max in IC.)

Wiring 6.png


Now for something more advanced, the MFE. This is an example of an improper setup of an MFE before I place the 2 wires in the second picture

Wiring 7.png


and after I placed the 2 wires above the HVT

Wiring 8.png


this caused a loop of power to be sent from the top of the MFE(output) back into the batBox hence killing the setup.(and wasting the wire because it couldnt handle the power and just melted) To properly use a MFE, you need to use a [[LV_Transformer|Low Voltage Transformer. the MFE is used to scale the voltage up and the Low voltage transformer to scale it back down. Quite similar to real life and your local power grid.doing this increases the range of the power but needs a better Cable. The energy loss is less because you are sending less packets that are larger, they still lose EU over the cable but you lose less.

Wiring 9.png


Next is series of machines, and current splitting. You can have you machines in a row and power them from one MFE the excess is sent back to the MFE and stored. I this setup I have the maximum cable length without loss (to prevent continuous loss of power) and the measurements listed are from right to left and the last one receiving 0 EU. the Eu splits evenly between each machine as it acts like a cable end.

Wiring 10.png


and this is with an MFE output of 50EUs

Wiring 11.png


as you can see it is useless to make lines of machines any longer than 5 and 4 would be optimal as the last 2 would receive 8/2 = 4 EU each, which will power most common machines easily. You could use the 50 EU output if you wanted to power say 4 crystal chargers in a row.

You can then save space and stack your machines in a feasible 3x4 array like so.

Wiring 12.png


and the back to power them

Wiring 13.png


Next up is Miners and making them do what you want them to. I the first setup I have a solar flower powering a MFE => HVT => HVT => Miner. This is a one way operation, but the miner can only accept so much EU at a time therefore the 2000 EU sent towards the miner will sometimes be rejected and get sent back. causing loss each way. This can happen as often as once each frame causing massive power loss.

Wiring 14.png


A better way to do it is using Switch Cables. these accept input on all sides but the bottom, (which is the output). However if you apply Redstone current it will make the top output and the bottom input. This can be used as a switch before sending Eu from the MFE =>HVT. This way you can shut the whole operation down and let the MFEs charge up.

Wiring 15.png

The miner can be set up to automate with water streams as well. however I use Feanorith's Mine Factory Mod that lets you build a conveyor. This is easier then digging trenches and placing water buckets. It also can travel ridiculously long lengths, and never have to dig one block down. This is similar to water running on iceblocks (if you can craft em)

Wiring 16.png


Take note that I have all but one of the 5 available sides of the miner covered as to direct the item toward the conveyor, and a small 3 long wall to stop the items from being shot over the conveyor.