Difference between revisions of "Reactor Heat Vent"

From Industrial-Craft-Wiki
Jump to navigation Jump to search
(Added IC2 experimental recipe)
m
 
(5 intermediate revisions by 5 users not shown)
Line 1: Line 1:
This is an upgraded [[Heat Vent|heat vent]] that transfers 5 heat from the reactor to itself and cools itself by 5 (every reactor tick), but applies NO cooling to nearby components.  
{{Experimental}}
== Recipe (IC² Experimental) ==
 
The '''Reactor Heat Vent''' is a heat vent that removes heat from the hull of a {{Gin|Nuclear Reactor}} at an increased rate.  
 
== Recipe ==
=== Experimental ===
{{Grid/Crafting Table
{{Grid/Crafting Table
|A1=Copper Plate|B1=Copper Plate|C1=Copper Plate
|A1=Copper Plate|B1=Copper Plate|C1=Copper Plate
Line 8: Line 12:
}}
}}


== Recipe ==
=== Legacy ===
{{Grid/Crafting Table
{{Grid/Crafting Table
|A1=|B1=Dense Copper Plate|C1=
|A1=|B1=Dense Copper Plate|C1=
Line 16: Line 20:
}}
}}


{{Navigation}}
== Usage ==
The Reactor Heat Vent removes heat from itself and from the reactor hull.
 
{| class="wikitable"
|+ Heat Management
! scope="row" style="text-align: left;"|Heat Capacity
|? [[hU]]
|-
! scope="row" style="text-align: left;"|Self Venting Rate
|5 hU/s
|-
! scope="row" style="text-align: left;"|Hull Venting Rate
|5 hU/s
|-
! scope="row" style="text-align: left;"|Component Venting Rate
|<nowiki>---</nowiki>
|}
Self Venting Rate ''refers to the amount of heat the Heat Vent will vent from itself per reactor tick''
 
Hull Venting Rate ''refers to the amount of heat the Heat Vent will remove from the reactor hull per reactor tick''
 
Component Venting Rate ''refers to the amount of heat the Heat Vent will remove from adjacent components per reactor tick''


[[Category:Nuclear Reactor]]
[[Category:Reactor Components]]

Latest revision as of 07:10, 10 April 2017

Experimental-Only Content: This information has been updated to the V2.X version of IC².
The most recent version of IC² is V2.8.<html>.

The Reactor Heat Vent is a heat vent that removes heat from the hull of a Grid Nuclear Reactor.png Nuclear Reactor at an increased rate.

Recipe[edit]

Experimental[edit]

Grid Copper Plate.png
Grid Copper Plate.png
Grid Copper Plate.png
Grid Copper Plate.png
Grid Heat Vent.png
Grid Copper Plate.png
Grid Copper Plate.png
Grid Copper Plate.png
Grid Copper Plate.png
Grid Reactor Heat Vent.png


Legacy[edit]



Grid Dense Copper Plate.png
Grid Heat Vent.png
Grid Dense Copper Plate.png



Grid Reactor Heat Vent.png


Usage[edit]

The Reactor Heat Vent removes heat from itself and from the reactor hull.

Heat Management
Heat Capacity ? hU
Self Venting Rate 5 hU/s
Hull Venting Rate 5 hU/s
Component Venting Rate ---

Self Venting Rate refers to the amount of heat the Heat Vent will vent from itself per reactor tick

Hull Venting Rate refers to the amount of heat the Heat Vent will remove from the reactor hull per reactor tick

Component Venting Rate refers to the amount of heat the Heat Vent will remove from adjacent components per reactor tick