Difference between revisions of "Overclocked Heat Vent"

From Industrial-Craft-Wiki
Jump to navigation Jump to search
m
m
 
Line 1: Line 1:
Special version of [[Reactor Heat Vent]].<br />
{{Experimental}}
Draws heat directly from reactor hull, but will self-destruct if no external cooling is provided.


Each reactor tick, the [[Overclocked Heat Vent]] will draw up to 36 heat from the reactor hull, then cool itself by 20 heat. This component will easily overheat and destroy itself unless heat exchangers are used to balance heat.  
The '''Overclocked Heat Vent''' is a heat vent that removes heat from itself and from the hull of a {{Gin|Nuclear Reactor}} at an increased rate.


== Recipe ==
{{Grid/Crafting Table
{{Grid/Crafting Table
|A2=Gold Plate
|A2=Gold Plate
Line 11: Line 11:
}}
}}


See: [http://crafting-guide.com/item/overclocked_heat_vent Crafting Guide]


== Usage ==
The Overclocked Heat Vent removes heat from itself and from the reactor hull.


{| class="wikitable"
|+ Heat Management
! scope="row" style="text-align: left;"|Heat Capacity
|? [[hU]]
|-
! scope="row" style="text-align: left;"|Self Venting Rate
|20 hU/s
|-
! scope="row" style="text-align: left;"|Hull Venting Rate
|36 hU/s
|-
! scope="row" style="text-align: left;"|Component Venting Rate
|<nowiki>---</nowiki>
|}
Self Venting Rate ''refers to the amount of heat the Heat Vent will vent from itself per reactor tick''


[[Category:Nuclear Reactor]]
Hull Venting Rate ''refers to the amount of heat the Heat Vent will remove from the reactor hull per reactor tick''
[[Category:Heat Vents]]
 
Component Venting Rate ''refers to the amount of heat the Heat Vent will remove from adjacent components per reactor tick''
 
[[Category:Reactor Components]]

Latest revision as of 07:10, 10 April 2017

Experimental-Only Content: This information has been updated to the V2.X version of IC².
The most recent version of IC² is V2.8.<html>.

The Overclocked Heat Vent is a heat vent that removes heat from itself and from the hull of a Grid Nuclear Reactor.png Nuclear Reactor at an increased rate.

Recipe[edit]


Grid Gold Plate.png


Grid Gold Plate.png
Grid Reactor Heat Vent.png
Grid Gold Plate.png


Grid Gold Plate.png


Grid Overclocked Heat Vent.png



Usage[edit]

The Overclocked Heat Vent removes heat from itself and from the reactor hull.

Heat Management
Heat Capacity ? hU
Self Venting Rate 20 hU/s
Hull Venting Rate 36 hU/s
Component Venting Rate ---

Self Venting Rate refers to the amount of heat the Heat Vent will vent from itself per reactor tick

Hull Venting Rate refers to the amount of heat the Heat Vent will remove from the reactor hull per reactor tick

Component Venting Rate refers to the amount of heat the Heat Vent will remove from adjacent components per reactor tick