{{Block
#REDIRECT [[Transformer#LV-Transformer]]
|image=
|type=Wiring
|gravity=No
|dirt=No
|transparent=No
|light=no
|tool=bwrench
|stackable=Yes (64)
}}
 
{{IC²}}
 
The Low Voltage Transformer is used to turn '''Medium Voltage''' (MV) [[EU]] current into '''Low Voltage''' (LV) and back. This is useful for powering basic machines.
 
MV current must be wired into the High Voltage face (the 3-dotted one), while LV current can be wired into any other face. By default, the Transformer outputs LV current. A Redstone signal must be applied to it in order to make it reverse flow, thereby emitting MV current from the High Voltage face (the 3-dotted one).
 
It can handle a maximum of one conversion per tick, limiting the maximum transfer to 128 EU/t in either mode.
 
== Recipe ==
 
{{Grid/Crafting Table
|A1=Wooden Planks|B1=Insulated Copper Cable|C1=Wooden Planks
|A2=Copper|B2=Copper|C2=Copper
|A3=Wooden Planks|B3=Insulated Copper Cable|C3=Wooden Planks
|Output=LV Transformer
}}
 
== Usage ==
 
When using any Transformer, remember that the 3-dotted side means '''higher current''' and the 1-dotted sides mean '''lower current'''. You can change the direction the 3-dotted side is facing by right-clicking a 1-dotted face with a [[Wrench]].
 
=== Converting to LV: ===
 
In order to convert from MV to LV, you must point the [[Cable|cable]] carrying MV from a [[MV Transformer]] or [[MFE Unit]] to the 3-dotted side and then link a cable to one of the sides with a single dot. Then that cable will be carrying LV that you can safely link to machines or store in a [[BatBox]].
 
=== Converting to MV: ===
 
In order to convert from LV to MV, point the cable carrying LV from a [[BatBox]] or a [[Generator]] to one of the one-dotted sides and then link a cable that can carry MV to the 3-dotted side. '''Do not forget to apply Redstone''' to the LV Transformer.
 
{{Energy|Input=32 or 128|Output=32 or 128|Storage=-}}
 