Difference between revisions of "Component Heat Vent"

From Industrial-Craft-Wiki
Jump to navigation Jump to search
(Undo revision 18492 by Stunod (talk) Please avoid removing the HAYO section.)
m
 
Line 1: Line 1:
The component heat vent is an upgraded [[Heat Vent]] that applies 4 cooling to nearby components (a larger amount instead of some amount), but doesn't apply ANY cooling to the reactor hull. They can cool a full-working [[Overclocked Heat Vent]] if placed in the right way creating a good reactor system.
{{Experimental}}


{| class="wikitable"
The '''Component Heat Vent''' is a heat vent that removes heat from adjacent components at an increased rate.
|+ One Example
| [[Uranium Cell]] || ''empty space'' || [[Uranium Cell]]
|-
| ''empty space'' || [[Overclocked Heat Vent]] || [[Component Heat Vent]]
|-
| [[Uranium Cell]] || [[Component Heat Vent]] || [[Uranium Cell]]
|-
| [[Uranium Cell]] || [[Component Heat Vent]] || [[Uranium Cell]]
|-
| [[Overclocked Heat Vent ]] || [[Component Heat Vent]] || [[Overclocked Heat Vent]]
|-
| [[Uranium Cell]] || [[Component Heat Vent]] || [[Uranium Cell]]
|}


== Recipe ==
== Recipe ==
Line 24: Line 11:
}}
}}


See: [http://crafting-guide.com/item/component_heat_vent Crafting Guide]
== Usage ==
The Component Heat Vent removes heat from adjacent reactor components.
 
{| class="wikitable"
|+ Heat Management
! scope="row" style="text-align: left;"|Heat Capacity
|<nowiki>---</nowiki>
|-
! scope="row" style="text-align: left;"|Self Venting Rate
|<nowiki>---</nowiki>
|-
! scope="row" style="text-align: left;"|Hull Venting Rate
|<nowiki>---</nowiki>
|-
! scope="row" style="text-align: left;"|Component Venting Rate
|4 hU/s
|}
Self Venting Rate ''refers to the amount of heat the Heat Vent will vent from itself per reactor tick''
 
Hull Venting Rate ''refers to the amount of heat the Heat Vent will remove from the reactor hull per reactor tick''
 
Component Venting Rate ''refers to the amount of heat the Heat Vent will remove from adjacent components per reactor tick''
 
== Example Reactor Design ==
{| class="wikitable"
| {{Gc|Uranium Cell}}
|
| {{Gc|Uranium Cell}}
|-
| {{Gc|Component Heat Vent}}
| {{Gc|Overclocked Heat Vent}}
| {{Gc|Component Heat Vent}}
|-
| {{Gc|Uranium Cell}}
| {{Gc|Component Heat Vent}}
| {{Gc|Uranium Cell}}
|-
| {{Gc|Uranium Cell}}
| {{Gc|Component Heat Vent}}
| {{Gc|Uranium Cell}}
|-
| {{Gc|Overclocked Heat Vent }}
| {{Gc|Component Heat Vent}}
| {{Gc|Overclocked Heat Vent}}
|-
| {{Gc|Uranium Cell}}
| {{Gc|Component Heat Vent}}
| {{Gc|Uranium Cell}}
|}


== HAYO ==
== HAYO ==
This vent doesn't dissipate any reactor heat. But seriously, who cares? It cools your components preventing them from melting! HAYO!
This vent doesn't dissipate any reactor heat. But seriously, who cares? It cools your components preventing them from melting! HAYO!


 
[[Category:Reactor Components]]
 
[[Category:Nuclear Reactor]]
[[Category:Heat Vents]]

Latest revision as of 06:49, 10 April 2017

Experimental-Only Content: This information has been updated to the V2.X version of IC².
The most recent version of IC² is V2.8.<html>.

The Component Heat Vent is a heat vent that removes heat from adjacent components at an increased rate.

Recipe[edit]

Grid Iron Bars.png
Grid Tin Plate.png
Grid Iron Bars.png
Grid Tin Plate.png
Grid Heat Vent.png
Grid Tin Plate.png
Grid Iron Bars.png
Grid Tin Plate.png
Grid Iron Bars.png
Grid Component Heat Vent.png


Usage[edit]

The Component Heat Vent removes heat from adjacent reactor components.

Heat Management
Heat Capacity ---
Self Venting Rate ---
Hull Venting Rate ---
Component Venting Rate 4 hU/s

Self Venting Rate refers to the amount of heat the Heat Vent will vent from itself per reactor tick

Hull Venting Rate refers to the amount of heat the Heat Vent will remove from the reactor hull per reactor tick

Component Venting Rate refers to the amount of heat the Heat Vent will remove from adjacent components per reactor tick

Example Reactor Design[edit]

Grid Uranium Cell.png
Grid Uranium Cell.png
Grid Component Heat Vent.png
Grid Overclocked Heat Vent.png
Grid Component Heat Vent.png
Grid Uranium Cell.png
Grid Component Heat Vent.png
Grid Uranium Cell.png
Grid Uranium Cell.png
Grid Component Heat Vent.png
Grid Uranium Cell.png
Grid Overclocked Heat Vent.png
Grid Component Heat Vent.png
Grid Overclocked Heat Vent.png
Grid Uranium Cell.png
Grid Component Heat Vent.png
Grid Uranium Cell.png

HAYO[edit]

This vent doesn't dissipate any reactor heat. But seriously, who cares? It cools your components preventing them from melting! HAYO!