<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://wiki.industrial-craft.net/api.php?action=feedcontributions&amp;feedformat=atom&amp;user=Fern+Silverthorn</id>
	<title>Industrial-Craft-Wiki - User contributions [en]</title>
	<link rel="self" type="application/atom+xml" href="https://wiki.industrial-craft.net/api.php?action=feedcontributions&amp;feedformat=atom&amp;user=Fern+Silverthorn"/>
	<link rel="alternate" type="text/html" href="https://wiki.industrial-craft.net/index.php?title=Special:Contributions/Fern_Silverthorn"/>
	<updated>2026-10-16T09:45:06Z</updated>
	<subtitle>User contributions</subtitle>
	<generator>MediaWiki 1.37.1</generator>
	<entry>
		<id>https://wiki.industrial-craft.net/index.php?title=HV_Transformer&amp;diff=15170</id>
		<title>HV Transformer</title>
		<link rel="alternate" type="text/html" href="https://wiki.industrial-craft.net/index.php?title=HV_Transformer&amp;diff=15170"/>
		<updated>2015-01-19T22:43:32Z</updated>

		<summary type="html">&lt;p&gt;Fern Silverthorn: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{Block&lt;br /&gt;
|type=Transformer&lt;br /&gt;
|gravity=No&lt;br /&gt;
|dirt=No&lt;br /&gt;
|transparent=No&lt;br /&gt;
|light=No&lt;br /&gt;
|tool=bwrench&lt;br /&gt;
|stackable=Yes (64)&lt;br /&gt;
|maxeu=2048&lt;br /&gt;
}}&lt;br /&gt;
&lt;br /&gt;
Unlike Real Life&amp;amp;trade;, there is no actual &amp;quot;voltage&amp;quot; in IC². EU travels in &amp;quot;packets&amp;quot; through wires with near-infinite speed and has smart pathfinding (somewhat like RP2 pneumatic tubes). Packets are measured in size (in EU/p) and volume (EU). (Size being the amount of energy it contains as it leaves a storage unit, volume being how much energy is left in each packet after inefficient cable usage).&lt;br /&gt;
&lt;br /&gt;
Transformers have two modes - &amp;quot;step up&amp;quot; and &amp;quot;step down&amp;quot;. By default, the transformer will be in step up mode when it receives a redstone signal, and step down mode otherwise. This can be changed in the GUI. &lt;br /&gt;
&lt;br /&gt;
With default settings a HVT (or High Voltage Transformer) operates in two different ways.&lt;br /&gt;
&lt;br /&gt;
* If redstone power is &amp;#039;&amp;#039;&amp;#039;not&amp;#039;&amp;#039;&amp;#039; applied, it consumes 2048 EU in &amp;#039;&amp;#039;&amp;#039;any packet size&amp;#039;&amp;#039;&amp;#039; and converts them into up to four 512 EU/p. &amp;#039;&amp;#039;&amp;#039;All conversions are limited to one per tick. (Converting 2048 EU into 4x512 EU is considered one conversion.)&amp;#039;&amp;#039;&amp;#039;&lt;br /&gt;
* If redstone power is applied, it consumes 2048 EU in &amp;#039;&amp;#039;&amp;#039;any packet size&amp;#039;&amp;#039;&amp;#039; and converts them into one 2048 EU/p. &amp;#039;&amp;#039;&amp;#039;All conversions are limited to one per tick.&amp;#039;&amp;#039;&amp;#039;&lt;br /&gt;
=== Converting to HV ===&lt;br /&gt;
In order to convert to HV, you must point the input cable (any &amp;quot;voltage&amp;quot;) to the 3-dotted side and then link any number of output cables from the 1-dotted side. Remember to use input cables that can withstand the packets you are sending in and [[HV Cable]] or [[Glass Fibre Cable]] for the output.&lt;br /&gt;
&lt;br /&gt;
=== Converting to EV ===&lt;br /&gt;
In order to convert to EV, you must &amp;#039;&amp;#039;&amp;#039;apply redstone power through a lever, a repeater or a redstone wire&amp;#039;&amp;#039;&amp;#039;, point the input cables (any &amp;quot;voltage&amp;quot;) to any 1-dotted side and then link the output cable from the 3-dotted side. Remember to use input cables that can withstand the packets you are sending in and [[HV Cable]] for the output.&lt;br /&gt;
&lt;br /&gt;
== Recipe ==&lt;br /&gt;
{{Experimental}}&lt;br /&gt;
{{Grid/Crafting Table&lt;br /&gt;
|B1=2xIns. Gold Cable&lt;br /&gt;
|A2=Electronic Circuit|B2=MV Transformer|C2=Advanced RE-Battery&lt;br /&gt;
|B3=2xIns. Gold Cable&lt;br /&gt;
|Output=HV Transformer&lt;br /&gt;
}}&lt;br /&gt;
&lt;br /&gt;
{{Energy&lt;br /&gt;
|Input= 2048 &amp;#039;&amp;#039;&amp;#039;EU&amp;#039;&amp;#039;&amp;#039;&lt;br /&gt;
|Output= Variable&lt;br /&gt;
* Up to 2048 EU in 512 EU/p when redstone is &amp;#039;&amp;#039;&amp;#039;not&amp;#039;&amp;#039;&amp;#039; applied.&lt;br /&gt;
* 1 packet of 2048 EU/p when redstone is applied.&lt;br /&gt;
|Storage=2048}}&lt;br /&gt;
&lt;br /&gt;
== Usage ==&lt;br /&gt;
{{Grid/Crafting Table&lt;br /&gt;
|B1=4xIns. HV Cable&lt;br /&gt;
|A2=Advanced Circuit|B2=HV Transformer|C2=Energy Crystal&lt;br /&gt;
|B3=4xIns. HV Cable&lt;br /&gt;
|Output=EV Transformer&lt;br /&gt;
}}&lt;br /&gt;
&lt;br /&gt;
== History (IC²) ==&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! IC²&lt;br /&gt;
! Minecraft&lt;br /&gt;
! Change&lt;br /&gt;
|-&lt;br /&gt;
| colspan=3 | Industrial Craft²&lt;br /&gt;
|-&lt;br /&gt;
! 2.0&lt;br /&gt;
| 1.6.4&lt;br /&gt;
| Before this version of IC², the [[HV Transformer]] was crafted using this recipe: &amp;lt;br/&amp;gt;&lt;br /&gt;
{{Grid/Crafting Table&lt;br /&gt;
|B1=4xIns. HV Cable&lt;br /&gt;
|A2=Electronic Circuit|B2=MV Transformer|C2=Energy Crystal&lt;br /&gt;
|B3=4xIns. HV Cable&lt;br /&gt;
|Output=HV Transformer&lt;br /&gt;
}}&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Other usages ==&lt;br /&gt;
Multiple HVT may be directly installed on a [[Nuclear Reactor]] if the reactor outputs more than 2048 EU/t as conventional wires ([[HV cables]]) cannot handle packet sizes over 2048 EU/p.&lt;br /&gt;
&lt;br /&gt;
{{Navigation}}&lt;br /&gt;
&lt;br /&gt;
[[Category:Wiring]]&lt;/div&gt;</summary>
		<author><name>Fern Silverthorn</name></author>
	</entry>
	<entry>
		<id>https://wiki.industrial-craft.net/index.php?title=MV_Transformer&amp;diff=15169</id>
		<title>MV Transformer</title>
		<link rel="alternate" type="text/html" href="https://wiki.industrial-craft.net/index.php?title=MV_Transformer&amp;diff=15169"/>
		<updated>2015-01-19T22:41:47Z</updated>

		<summary type="html">&lt;p&gt;Fern Silverthorn: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{Block&lt;br /&gt;
|image=&lt;br /&gt;
|type=Wiring&lt;br /&gt;
|gravity=No&lt;br /&gt;
|dirt=No&lt;br /&gt;
|transparent=No&lt;br /&gt;
|light=no&lt;br /&gt;
|tool=bwrench&lt;br /&gt;
|stackable=Yes (64)&lt;br /&gt;
}}&lt;br /&gt;
&lt;br /&gt;
{{IC²}}&lt;br /&gt;
&lt;br /&gt;
The MV Transformer is used to turn &amp;#039;&amp;#039;&amp;#039;High Power&amp;#039;&amp;#039;&amp;#039; (512 [[EU#EU-Packet|EUP]]) into &amp;#039;&amp;#039;&amp;#039;Medium Power&amp;#039;&amp;#039;&amp;#039; (128 EUP) and back. This is useful for powering advanced machines and for medium-range energy transport.&lt;br /&gt;
&lt;br /&gt;
By default, the Transformer accepts 512 [[EU#EU-Packet|EUP]] input and outputs 128 EUP. A 512 EUP or higher rated [[cable]] must be wired into the input face (the 3-dotted one) and 128 EUP or higher rated cable must be wired into the other faces.&lt;br /&gt;
&lt;br /&gt;
Transformers have two modes - &amp;quot;step up&amp;quot; and &amp;quot;step down&amp;quot;. By default, the transformer will be in step up mode when it receives a redstone signal, and step down mode otherwise. This can be changed in the GUI. &lt;br /&gt;
&lt;br /&gt;
With default settings a Redstone signal may be applied to reverse the conversion, thereby emitting 512 [[EU#EU-Packet|EUP]] from the output face (the 3-dotted one), and accepting 128 EUP or lower from the input faces. In reverse operation, 512 EUP or higher rated [[cable]] must be wired to the output face and any rate cable may be wired to the input faces.&lt;br /&gt;
&lt;br /&gt;
It can handle a maximum of one conversion per tick, limiting the maximum transfer to 512 [[EU#EU/t|EU/t]] in either mode.&lt;br /&gt;
&lt;br /&gt;
== Recipe ==&lt;br /&gt;
{{Experimental}}&lt;br /&gt;
{{Grid/Crafting Table&lt;br /&gt;
|A1=|B1=Insulated Copper Cable|C1=&lt;br /&gt;
|A2=|B2=Machine|C2=&lt;br /&gt;
|A3=|B3=Insulated Copper Cable|C3=&lt;br /&gt;
|Output=MV Transformer&lt;br /&gt;
}}&lt;br /&gt;
&lt;br /&gt;
== Usage ==&lt;br /&gt;
&lt;br /&gt;
When using any Transformer, remember that the 3-dotted side means &amp;#039;&amp;#039;&amp;#039;higher current&amp;#039;&amp;#039;&amp;#039; and the 1-dotted sides mean &amp;#039;&amp;#039;&amp;#039;lower current&amp;#039;&amp;#039;&amp;#039;. You can change the direction the 3-dotted side is facing by right-clicking a 1-dotted face with a [[Wrench]].&lt;br /&gt;
&lt;br /&gt;
=== Converting to MV: ===&lt;br /&gt;
&lt;br /&gt;
In order to convert from HV to MV, you must point the [[Cable|cable]] carrying HV from a [[HV Transformer]] or [[MFS Unit]] to the 3-dotted side and then link a cable that can carry MV to one of the sides with a single dot. Then that cable will be carrying MV that you can link to advanced machines, store in a [[MFE Transmitter]] or convert to LV with an [[LV Transformer]].&lt;br /&gt;
&lt;br /&gt;
=== Converting to HV: ===&lt;br /&gt;
&lt;br /&gt;
In order to convert from MV to HV, point the cable carrying MV from a [[MFE Transmitter]] or a [[LV Transformer]] to one of the one-dotted sides and then link a cable that can carry HV to the 3-dotted side. &amp;#039;&amp;#039;&amp;#039;Do not forget to apply redstone&amp;#039;&amp;#039;&amp;#039; to the MV Transformer.&lt;br /&gt;
&lt;br /&gt;
{{Energy|Input=128 or 512|Output=128 or 512|Storage=-}}&lt;br /&gt;
&lt;br /&gt;
{{Navigation}}&lt;/div&gt;</summary>
		<author><name>Fern Silverthorn</name></author>
	</entry>
	<entry>
		<id>https://wiki.industrial-craft.net/index.php?title=HV_Transformer&amp;diff=15168</id>
		<title>HV Transformer</title>
		<link rel="alternate" type="text/html" href="https://wiki.industrial-craft.net/index.php?title=HV_Transformer&amp;diff=15168"/>
		<updated>2015-01-19T22:39:11Z</updated>

		<summary type="html">&lt;p&gt;Fern Silverthorn: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{Block&lt;br /&gt;
|type=Transformer&lt;br /&gt;
|gravity=No&lt;br /&gt;
|dirt=No&lt;br /&gt;
|transparent=No&lt;br /&gt;
|light=No&lt;br /&gt;
|tool=bwrench&lt;br /&gt;
|stackable=Yes (64)&lt;br /&gt;
|maxeu=2048&lt;br /&gt;
}}&lt;br /&gt;
&lt;br /&gt;
Unlike Real Life&amp;amp;trade;, there is no actual &amp;quot;voltage&amp;quot; in IC². EU travels in &amp;quot;packets&amp;quot; through wires with near-infinite speed and has smart pathfinding (somewhat like RP2 pneumatic tubes). Packets are measured in size (in EU/p) and volume (EU). (Size being the amount of energy it contains as it leaves a storage unit, volume being how much energy is left in each packet after inefficient cable usage).&lt;br /&gt;
&lt;br /&gt;
A HVT (or High Voltage Transformer) operates in two different ways.&lt;br /&gt;
&lt;br /&gt;
* If redstone power is &amp;#039;&amp;#039;&amp;#039;not&amp;#039;&amp;#039;&amp;#039; applied, it consumes 2048 EU in &amp;#039;&amp;#039;&amp;#039;any packet size&amp;#039;&amp;#039;&amp;#039; and converts them into up to four 512 EU/p. &amp;#039;&amp;#039;&amp;#039;All conversions are limited to one per tick. (Converting 2048 EU into 4x512 EU is considered one conversion.)&amp;#039;&amp;#039;&amp;#039;&lt;br /&gt;
* If redstone power is applied, it consumes 2048 EU in &amp;#039;&amp;#039;&amp;#039;any packet size&amp;#039;&amp;#039;&amp;#039; and converts them into one 2048 EU/p. &amp;#039;&amp;#039;&amp;#039;All conversions are limited to one per tick.&amp;#039;&amp;#039;&amp;#039;&lt;br /&gt;
=== Converting to HV ===&lt;br /&gt;
In order to convert to HV, you must point the input cable (any &amp;quot;voltage&amp;quot;) to the 3-dotted side and then link any number of output cables from the 1-dotted side. Remember to use input cables that can withstand the packets you are sending in and [[HV Cable]] or [[Glass Fibre Cable]] for the output.&lt;br /&gt;
&lt;br /&gt;
=== Converting to EV ===&lt;br /&gt;
In order to convert to EV, you must &amp;#039;&amp;#039;&amp;#039;apply redstone power through a lever, a repeater or a redstone wire&amp;#039;&amp;#039;&amp;#039;, point the input cables (any &amp;quot;voltage&amp;quot;) to any 1-dotted side and then link the output cable from the 3-dotted side. Remember to use input cables that can withstand the packets you are sending in and [[HV Cable]] for the output.&lt;br /&gt;
&lt;br /&gt;
== Recipe ==&lt;br /&gt;
{{Experimental}}&lt;br /&gt;
Behavior may also be controlled with the transformer GUI, modes include: Fixed up/down and redstone controlled. &lt;br /&gt;
&lt;br /&gt;
{{Grid/Crafting Table&lt;br /&gt;
|B1=2xIns. Gold Cable&lt;br /&gt;
|A2=Electronic Circuit|B2=MV Transformer|C2=Advanced RE-Battery&lt;br /&gt;
|B3=2xIns. Gold Cable&lt;br /&gt;
|Output=HV Transformer&lt;br /&gt;
}}&lt;br /&gt;
&lt;br /&gt;
{{Energy&lt;br /&gt;
|Input= 2048 &amp;#039;&amp;#039;&amp;#039;EU&amp;#039;&amp;#039;&amp;#039;&lt;br /&gt;
|Output= Variable&lt;br /&gt;
* Up to 2048 EU in 512 EU/p when redstone is &amp;#039;&amp;#039;&amp;#039;not&amp;#039;&amp;#039;&amp;#039; applied.&lt;br /&gt;
* 1 packet of 2048 EU/p when redstone is applied.&lt;br /&gt;
|Storage=2048}}&lt;br /&gt;
&lt;br /&gt;
== Usage ==&lt;br /&gt;
{{Grid/Crafting Table&lt;br /&gt;
|B1=4xIns. HV Cable&lt;br /&gt;
|A2=Advanced Circuit|B2=HV Transformer|C2=Energy Crystal&lt;br /&gt;
|B3=4xIns. HV Cable&lt;br /&gt;
|Output=EV Transformer&lt;br /&gt;
}}&lt;br /&gt;
&lt;br /&gt;
== History (IC²) ==&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! IC²&lt;br /&gt;
! Minecraft&lt;br /&gt;
! Change&lt;br /&gt;
|-&lt;br /&gt;
| colspan=3 | Industrial Craft²&lt;br /&gt;
|-&lt;br /&gt;
! 2.0&lt;br /&gt;
| 1.6.4&lt;br /&gt;
| Before this version of IC², the [[HV Transformer]] was crafted using this recipe: &amp;lt;br/&amp;gt;&lt;br /&gt;
{{Grid/Crafting Table&lt;br /&gt;
|B1=4xIns. HV Cable&lt;br /&gt;
|A2=Electronic Circuit|B2=MV Transformer|C2=Energy Crystal&lt;br /&gt;
|B3=4xIns. HV Cable&lt;br /&gt;
|Output=HV Transformer&lt;br /&gt;
}}&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Other usages ==&lt;br /&gt;
Multiple HVT may be directly installed on a [[Nuclear Reactor]] if the reactor outputs more than 2048 EU/t as conventional wires ([[HV cables]]) cannot handle packet sizes over 2048 EU/p.&lt;br /&gt;
&lt;br /&gt;
{{Navigation}}&lt;br /&gt;
&lt;br /&gt;
[[Category:Wiring]]&lt;/div&gt;</summary>
		<author><name>Fern Silverthorn</name></author>
	</entry>
	<entry>
		<id>https://wiki.industrial-craft.net/index.php?title=MV_Transformer&amp;diff=15167</id>
		<title>MV Transformer</title>
		<link rel="alternate" type="text/html" href="https://wiki.industrial-craft.net/index.php?title=MV_Transformer&amp;diff=15167"/>
		<updated>2015-01-19T22:38:47Z</updated>

		<summary type="html">&lt;p&gt;Fern Silverthorn: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{Block&lt;br /&gt;
|image=&lt;br /&gt;
|type=Wiring&lt;br /&gt;
|gravity=No&lt;br /&gt;
|dirt=No&lt;br /&gt;
|transparent=No&lt;br /&gt;
|light=no&lt;br /&gt;
|tool=bwrench&lt;br /&gt;
|stackable=Yes (64)&lt;br /&gt;
}}&lt;br /&gt;
&lt;br /&gt;
{{IC²}}&lt;br /&gt;
&lt;br /&gt;
The MV Transformer is used to turn &amp;#039;&amp;#039;&amp;#039;High Power&amp;#039;&amp;#039;&amp;#039; (512 [[EU#EU-Packet|EUP]]) into &amp;#039;&amp;#039;&amp;#039;Medium Power&amp;#039;&amp;#039;&amp;#039; (128 EUP) and back. This is useful for powering advanced machines and for medium-range energy transport.&lt;br /&gt;
&lt;br /&gt;
By default, the Transformer accepts 512 [[EU#EU-Packet|EUP]] input and outputs 128 EUP. A 512 EUP or higher rated [[cable]] must be wired into the input face (the 3-dotted one) and 128 EUP or higher rated cable must be wired into the other faces.&lt;br /&gt;
&lt;br /&gt;
A Redstone signal may be applied to reverse the conversion, thereby emitting 512 [[EU#EU-Packet|EUP]] from the output face (the 3-dotted one), and accepting 128 EUP or lower from the input faces. In reverse operation, 512 EUP or higher rated [[cable]] must be wired to the output face and any rate cable may be wired to the input faces.&lt;br /&gt;
&lt;br /&gt;
It can handle a maximum of one conversion per tick, limiting the maximum transfer to 512 [[EU#EU/t|EU/t]] in either mode.&lt;br /&gt;
&lt;br /&gt;
== Recipe ==&lt;br /&gt;
{{Experimental}}&lt;br /&gt;
Behavior may also be controlled with the transformer GUI, modes include: Fixed up/down and redstone controlled. &lt;br /&gt;
&lt;br /&gt;
{{Grid/Crafting Table&lt;br /&gt;
|A1=|B1=Insulated Copper Cable|C1=&lt;br /&gt;
|A2=|B2=Machine|C2=&lt;br /&gt;
|A3=|B3=Insulated Copper Cable|C3=&lt;br /&gt;
|Output=MV Transformer&lt;br /&gt;
}}&lt;br /&gt;
&lt;br /&gt;
== Usage ==&lt;br /&gt;
&lt;br /&gt;
When using any Transformer, remember that the 3-dotted side means &amp;#039;&amp;#039;&amp;#039;higher current&amp;#039;&amp;#039;&amp;#039; and the 1-dotted sides mean &amp;#039;&amp;#039;&amp;#039;lower current&amp;#039;&amp;#039;&amp;#039;. You can change the direction the 3-dotted side is facing by right-clicking a 1-dotted face with a [[Wrench]].&lt;br /&gt;
&lt;br /&gt;
=== Converting to MV: ===&lt;br /&gt;
&lt;br /&gt;
In order to convert from HV to MV, you must point the [[Cable|cable]] carrying HV from a [[HV Transformer]] or [[MFS Unit]] to the 3-dotted side and then link a cable that can carry MV to one of the sides with a single dot. Then that cable will be carrying MV that you can link to advanced machines, store in a [[MFE Transmitter]] or convert to LV with an [[LV Transformer]].&lt;br /&gt;
&lt;br /&gt;
=== Converting to HV: ===&lt;br /&gt;
&lt;br /&gt;
In order to convert from MV to HV, point the cable carrying MV from a [[MFE Transmitter]] or a [[LV Transformer]] to one of the one-dotted sides and then link a cable that can carry HV to the 3-dotted side. &amp;#039;&amp;#039;&amp;#039;Do not forget to apply redstone&amp;#039;&amp;#039;&amp;#039; to the MV Transformer.&lt;br /&gt;
&lt;br /&gt;
{{Energy|Input=128 or 512|Output=128 or 512|Storage=-}}&lt;br /&gt;
&lt;br /&gt;
{{Navigation}}&lt;/div&gt;</summary>
		<author><name>Fern Silverthorn</name></author>
	</entry>
	<entry>
		<id>https://wiki.industrial-craft.net/index.php?title=HV_Cable&amp;diff=15165</id>
		<title>HV Cable</title>
		<link rel="alternate" type="text/html" href="https://wiki.industrial-craft.net/index.php?title=HV_Cable&amp;diff=15165"/>
		<updated>2015-01-19T01:09:08Z</updated>

		<summary type="html">&lt;p&gt;Fern Silverthorn: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;HV cables are the 4th tier of [[Cable|cables]]. They can tolerate &amp;#039;&amp;#039;&amp;#039;High Voltage&amp;#039;&amp;#039;&amp;#039; (512 [[EU|EU/t]]) and &amp;#039;&amp;#039;&amp;#039;Extreme Voltage&amp;#039;&amp;#039;&amp;#039; (2048 EU/t).&lt;br /&gt;
&lt;br /&gt;
== Recipe ==&lt;br /&gt;
{{Experimental}}&lt;br /&gt;
{|&lt;br /&gt;
|{{Grid/MetalFormer&lt;br /&gt;
|Mode=Extruding&lt;br /&gt;
|Top=Iron&lt;br /&gt;
|Bottom=RE Battery (Charged)&lt;br /&gt;
|Output=HV Cable|OA=4&lt;br /&gt;
}}&lt;br /&gt;
|{{Grid/Crafting Table&lt;br /&gt;
|A1=Rubber|B1=Rubber|C1=Rubber&lt;br /&gt;
|A2=HV Cable&lt;br /&gt;
|Output=3xIns. HV Cable&lt;br /&gt;
|Output-link=3xIns. HV Cable&lt;br /&gt;
}}&lt;br /&gt;
{{Grid/Crafting Table&lt;br /&gt;
|A1=Cutter|B1=Iron Plate&lt;br /&gt;
|Output=HV Cable&lt;br /&gt;
|OA=4&lt;br /&gt;
}}&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
{{Classic}}&lt;br /&gt;
HV-Cables have an extremely high distance-related energy loss. They can have 3 different levels of insulation. Considering that a shock from a poorly insulated HV cable will most likely prove fatal, it is recommended to insulate them well unless the cable is located in a completely unreachable area. Even then, insulation should be applied to reduce the massive energy losses.&lt;br /&gt;
{|&lt;br /&gt;
|{{Grid/Crafting Table&lt;br /&gt;
|A2=Refined Iron|B2=Refined Iron|C2=Refined Iron&lt;br /&gt;
|Output=HV Cable|OA=12&lt;br /&gt;
}}&lt;br /&gt;
|{{Grid/Crafting Table&lt;br /&gt;
|B1=Rubber&lt;br /&gt;
|A2=Rubber|B2=Refined Iron|C2=Rubber&lt;br /&gt;
|B3=Rubber&lt;br /&gt;
|Output=Insulated HV Cable|OA=4&lt;br /&gt;
}}&lt;br /&gt;
|}&lt;br /&gt;
{|&lt;br /&gt;
|{{Grid/Crafting Table&lt;br /&gt;
|A1=Rubber|B1=HV Cable&lt;br /&gt;
|Output=Insulated HV Cable&lt;br /&gt;
}}&lt;br /&gt;
|{{Grid/Crafting Table&lt;br /&gt;
|A1=Rubber|B1=Insulated HV Cable&lt;br /&gt;
|Output=2xIns. HV Cable&lt;br /&gt;
}}&lt;br /&gt;
|}&lt;br /&gt;
{|&lt;br /&gt;
|{{Grid/Crafting Table&lt;br /&gt;
|A1=Rubber|B1=Rubber|C1=HV Cable&lt;br /&gt;
|Output=2xIns. HV Cable&lt;br /&gt;
}}&lt;br /&gt;
|{{Grid/Crafting Table&lt;br /&gt;
|A1=Rubber|B1=Rubber|C1=Insulated HV Cable&lt;br /&gt;
|Output=3xIns. HV Cable&lt;br /&gt;
|Output-link=3xIns. HV Cable&lt;br /&gt;
}}&lt;br /&gt;
|}&lt;br /&gt;
{|&lt;br /&gt;
|{{Grid/Crafting Table&lt;br /&gt;
|A1=Rubber|B1=Rubber|C1=Rubber&lt;br /&gt;
|A2=HV Cable&lt;br /&gt;
|Output=3xIns. HV Cable&lt;br /&gt;
|Output-link=3xIns. HV Cable&lt;br /&gt;
}}&lt;br /&gt;
|{{Grid/Crafting Table&lt;br /&gt;
|A1=Rubber|B1=2xIns. HV Cable&lt;br /&gt;
|Output=3xIns. HV Cable&lt;br /&gt;
|Output-link=3xIns. HV Cable&lt;br /&gt;
}}&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
=== [[Cable#Cable Efficiency|Cable Efficiency]] ===&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
!Cable type&lt;br /&gt;
!EU/b&lt;br /&gt;
!Energy loss&lt;br /&gt;
|-&lt;br /&gt;
|HV Uninsulated&lt;br /&gt;
|1&lt;br /&gt;
|1 EU every block&lt;br /&gt;
|-&lt;br /&gt;
|HV Insulated&lt;br /&gt;
|0.95&lt;br /&gt;
|1 EU every 1.05 blocks&lt;br /&gt;
|-&lt;br /&gt;
|HV 2x Insulated&lt;br /&gt;
|0.9&lt;br /&gt;
|1 EU every 1.11 blocks&lt;br /&gt;
|-&lt;br /&gt;
|HV 3x Insulated&lt;br /&gt;
|0.8&lt;br /&gt;
|1 EU every 1.25 blocks&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
{{Navigation}}&lt;br /&gt;
&lt;br /&gt;
[[Category:Wiring]]&lt;/div&gt;</summary>
		<author><name>Fern Silverthorn</name></author>
	</entry>
	<entry>
		<id>https://wiki.industrial-craft.net/index.php?title=HV_Cable&amp;diff=15164</id>
		<title>HV Cable</title>
		<link rel="alternate" type="text/html" href="https://wiki.industrial-craft.net/index.php?title=HV_Cable&amp;diff=15164"/>
		<updated>2015-01-19T01:08:49Z</updated>

		<summary type="html">&lt;p&gt;Fern Silverthorn: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;HV cables are the 4 tier of [[Cable|cables]]. They can tolerate &amp;#039;&amp;#039;&amp;#039;High Voltage&amp;#039;&amp;#039;&amp;#039; (512 [[EU|EU/t]]) and &amp;#039;&amp;#039;&amp;#039;Extreme Voltage&amp;#039;&amp;#039;&amp;#039; (2048 EU/t).&lt;br /&gt;
&lt;br /&gt;
== Recipe ==&lt;br /&gt;
{{Experimental}}&lt;br /&gt;
{|&lt;br /&gt;
|{{Grid/MetalFormer&lt;br /&gt;
|Mode=Extruding&lt;br /&gt;
|Top=Iron&lt;br /&gt;
|Bottom=RE Battery (Charged)&lt;br /&gt;
|Output=HV Cable|OA=4&lt;br /&gt;
}}&lt;br /&gt;
|{{Grid/Crafting Table&lt;br /&gt;
|A1=Rubber|B1=Rubber|C1=Rubber&lt;br /&gt;
|A2=HV Cable&lt;br /&gt;
|Output=3xIns. HV Cable&lt;br /&gt;
|Output-link=3xIns. HV Cable&lt;br /&gt;
}}&lt;br /&gt;
{{Grid/Crafting Table&lt;br /&gt;
|A1=Cutter|B1=Iron Plate&lt;br /&gt;
|Output=HV Cable&lt;br /&gt;
|OA=4&lt;br /&gt;
}}&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
{{Classic}}&lt;br /&gt;
HV-Cables have an extremely high distance-related energy loss. They can have 3 different levels of insulation. Considering that a shock from a poorly insulated HV cable will most likely prove fatal, it is recommended to insulate them well unless the cable is located in a completely unreachable area. Even then, insulation should be applied to reduce the massive energy losses.&lt;br /&gt;
{|&lt;br /&gt;
|{{Grid/Crafting Table&lt;br /&gt;
|A2=Refined Iron|B2=Refined Iron|C2=Refined Iron&lt;br /&gt;
|Output=HV Cable|OA=12&lt;br /&gt;
}}&lt;br /&gt;
|{{Grid/Crafting Table&lt;br /&gt;
|B1=Rubber&lt;br /&gt;
|A2=Rubber|B2=Refined Iron|C2=Rubber&lt;br /&gt;
|B3=Rubber&lt;br /&gt;
|Output=Insulated HV Cable|OA=4&lt;br /&gt;
}}&lt;br /&gt;
|}&lt;br /&gt;
{|&lt;br /&gt;
|{{Grid/Crafting Table&lt;br /&gt;
|A1=Rubber|B1=HV Cable&lt;br /&gt;
|Output=Insulated HV Cable&lt;br /&gt;
}}&lt;br /&gt;
|{{Grid/Crafting Table&lt;br /&gt;
|A1=Rubber|B1=Insulated HV Cable&lt;br /&gt;
|Output=2xIns. HV Cable&lt;br /&gt;
}}&lt;br /&gt;
|}&lt;br /&gt;
{|&lt;br /&gt;
|{{Grid/Crafting Table&lt;br /&gt;
|A1=Rubber|B1=Rubber|C1=HV Cable&lt;br /&gt;
|Output=2xIns. HV Cable&lt;br /&gt;
}}&lt;br /&gt;
|{{Grid/Crafting Table&lt;br /&gt;
|A1=Rubber|B1=Rubber|C1=Insulated HV Cable&lt;br /&gt;
|Output=3xIns. HV Cable&lt;br /&gt;
|Output-link=3xIns. HV Cable&lt;br /&gt;
}}&lt;br /&gt;
|}&lt;br /&gt;
{|&lt;br /&gt;
|{{Grid/Crafting Table&lt;br /&gt;
|A1=Rubber|B1=Rubber|C1=Rubber&lt;br /&gt;
|A2=HV Cable&lt;br /&gt;
|Output=3xIns. HV Cable&lt;br /&gt;
|Output-link=3xIns. HV Cable&lt;br /&gt;
}}&lt;br /&gt;
|{{Grid/Crafting Table&lt;br /&gt;
|A1=Rubber|B1=2xIns. HV Cable&lt;br /&gt;
|Output=3xIns. HV Cable&lt;br /&gt;
|Output-link=3xIns. HV Cable&lt;br /&gt;
}}&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
=== [[Cable#Cable Efficiency|Cable Efficiency]] ===&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
!Cable type&lt;br /&gt;
!EU/b&lt;br /&gt;
!Energy loss&lt;br /&gt;
|-&lt;br /&gt;
|HV Uninsulated&lt;br /&gt;
|1&lt;br /&gt;
|1 EU every block&lt;br /&gt;
|-&lt;br /&gt;
|HV Insulated&lt;br /&gt;
|0.95&lt;br /&gt;
|1 EU every 1.05 blocks&lt;br /&gt;
|-&lt;br /&gt;
|HV 2x Insulated&lt;br /&gt;
|0.9&lt;br /&gt;
|1 EU every 1.11 blocks&lt;br /&gt;
|-&lt;br /&gt;
|HV 3x Insulated&lt;br /&gt;
|0.8&lt;br /&gt;
|1 EU every 1.25 blocks&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
{{Navigation}}&lt;br /&gt;
&lt;br /&gt;
[[Category:Wiring]]&lt;/div&gt;</summary>
		<author><name>Fern Silverthorn</name></author>
	</entry>
	<entry>
		<id>https://wiki.industrial-craft.net/index.php?title=HV_Transformer&amp;diff=15163</id>
		<title>HV Transformer</title>
		<link rel="alternate" type="text/html" href="https://wiki.industrial-craft.net/index.php?title=HV_Transformer&amp;diff=15163"/>
		<updated>2015-01-19T01:03:33Z</updated>

		<summary type="html">&lt;p&gt;Fern Silverthorn: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{Block&lt;br /&gt;
|type=Transformer&lt;br /&gt;
|gravity=No&lt;br /&gt;
|dirt=No&lt;br /&gt;
|transparent=No&lt;br /&gt;
|light=No&lt;br /&gt;
|tool=bwrench&lt;br /&gt;
|stackable=Yes (64)&lt;br /&gt;
|maxeu=2048&lt;br /&gt;
}}&lt;br /&gt;
&lt;br /&gt;
Unlike Real Life&amp;amp;trade;, there is no actual &amp;quot;voltage&amp;quot; in IC². EU travels in &amp;quot;packets&amp;quot; through wires with near-infinite speed and has smart pathfinding (somewhat like RP2 pneumatic tubes). Packets are measured in size (in EU/p) and volume (EU). (Size being the amount of energy it contains as it leaves a storage unit, volume being how much energy is left in each packet after inefficient cable usage).&lt;br /&gt;
&lt;br /&gt;
A HVT (or High Voltage Transformer) operates in two different ways.&lt;br /&gt;
&lt;br /&gt;
* If redstone power is &amp;#039;&amp;#039;&amp;#039;not&amp;#039;&amp;#039;&amp;#039; applied, it consumes 2048 EU in &amp;#039;&amp;#039;&amp;#039;any packet size&amp;#039;&amp;#039;&amp;#039; and converts them into up to four 512 EU/p. &amp;#039;&amp;#039;&amp;#039;All conversions are limited to one per tick. (Converting 2048 EU into 4x512 EU is considered one conversion.)&amp;#039;&amp;#039;&amp;#039;&lt;br /&gt;
* If redstone power is applied, it consumes 2048 EU in &amp;#039;&amp;#039;&amp;#039;any packet size&amp;#039;&amp;#039;&amp;#039; and converts them into one 2048 EU/p. &amp;#039;&amp;#039;&amp;#039;All conversions are limited to one per tick.&amp;#039;&amp;#039;&amp;#039;&lt;br /&gt;
=== Converting to HV ===&lt;br /&gt;
In order to convert to HV, you must point the input cable (any &amp;quot;voltage&amp;quot;) to the 3-dotted side and then link any number of output cables from the 1-dotted side. Remember to use input cables that can withstand the packets you are sending in and [[HV Cable]] or [[Glass Fibre Cable]] for the output.&lt;br /&gt;
&lt;br /&gt;
=== Converting to EV ===&lt;br /&gt;
In order to convert to EV, you must &amp;#039;&amp;#039;&amp;#039;apply redstone power through a lever, a repeater or a redstone wire&amp;#039;&amp;#039;&amp;#039;, point the input cables (any &amp;quot;voltage&amp;quot;) to any 1-dotted side and then link the output cable from the 3-dotted side. Remember to use input cables that can withstand the packets you are sending in and [[HV Cable]] for the output.&lt;br /&gt;
&lt;br /&gt;
== Recipe ==&lt;br /&gt;
{{Experimental}}&lt;br /&gt;
* In the Experimental version conversion direction and redstone behavior may also be controlled with the transformer GUI.&lt;br /&gt;
* Modes include: Fixed up/down and redstone controlled.&lt;br /&gt;
&lt;br /&gt;
{{Grid/Crafting Table&lt;br /&gt;
|B1=2xIns. Gold Cable&lt;br /&gt;
|A2=Electronic Circuit|B2=MV Transformer|C2=Advanced RE-Battery&lt;br /&gt;
|B3=2xIns. Gold Cable&lt;br /&gt;
|Output=HV Transformer&lt;br /&gt;
}}&lt;br /&gt;
&lt;br /&gt;
{{Energy&lt;br /&gt;
|Input= 2048 &amp;#039;&amp;#039;&amp;#039;EU&amp;#039;&amp;#039;&amp;#039;&lt;br /&gt;
|Output= Variable&lt;br /&gt;
* Up to 2048 EU in 512 EU/p when redstone is &amp;#039;&amp;#039;&amp;#039;not&amp;#039;&amp;#039;&amp;#039; applied.&lt;br /&gt;
* 1 packet of 2048 EU/p when redstone is applied.&lt;br /&gt;
|Storage=2048}}&lt;br /&gt;
&lt;br /&gt;
== Usage ==&lt;br /&gt;
{{Grid/Crafting Table&lt;br /&gt;
|B1=4xIns. HV Cable&lt;br /&gt;
|A2=Advanced Circuit|B2=HV Transformer|C2=Energy Crystal&lt;br /&gt;
|B3=4xIns. HV Cable&lt;br /&gt;
|Output=EV Transformer&lt;br /&gt;
}}&lt;br /&gt;
&lt;br /&gt;
== History (IC²) ==&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! IC²&lt;br /&gt;
! Minecraft&lt;br /&gt;
! Change&lt;br /&gt;
|-&lt;br /&gt;
| colspan=3 | Industrial Craft²&lt;br /&gt;
|-&lt;br /&gt;
! 2.0&lt;br /&gt;
| 1.6.4&lt;br /&gt;
| Before this version of IC², the [[HV Transformer]] was crafted using this recipe: &amp;lt;br/&amp;gt;&lt;br /&gt;
{{Grid/Crafting Table&lt;br /&gt;
|B1=4xIns. HV Cable&lt;br /&gt;
|A2=Electronic Circuit|B2=MV Transformer|C2=Energy Crystal&lt;br /&gt;
|B3=4xIns. HV Cable&lt;br /&gt;
|Output=HV Transformer&lt;br /&gt;
}}&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Other usages ==&lt;br /&gt;
Multiple HVT may be directly installed on a [[Nuclear Reactor]] if the reactor outputs more than 2048 EU/t as conventional wires ([[HV cables]]) cannot handle packet sizes over 2048 EU/p.&lt;br /&gt;
&lt;br /&gt;
{{Navigation}}&lt;br /&gt;
&lt;br /&gt;
[[Category:Wiring]]&lt;/div&gt;</summary>
		<author><name>Fern Silverthorn</name></author>
	</entry>
	<entry>
		<id>https://wiki.industrial-craft.net/index.php?title=HV_Transformer&amp;diff=15162</id>
		<title>HV Transformer</title>
		<link rel="alternate" type="text/html" href="https://wiki.industrial-craft.net/index.php?title=HV_Transformer&amp;diff=15162"/>
		<updated>2015-01-19T01:02:09Z</updated>

		<summary type="html">&lt;p&gt;Fern Silverthorn: Added experimental information.&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{Block&lt;br /&gt;
|type=Transformer&lt;br /&gt;
|gravity=No&lt;br /&gt;
|dirt=No&lt;br /&gt;
|transparent=No&lt;br /&gt;
|light=No&lt;br /&gt;
|tool=bwrench&lt;br /&gt;
|stackable=Yes (64)&lt;br /&gt;
|maxeu=2048&lt;br /&gt;
}}&lt;br /&gt;
&lt;br /&gt;
Unlike Real Life&amp;amp;trade;, there is no actual &amp;quot;voltage&amp;quot; in IC². EU travels in &amp;quot;packets&amp;quot; through wires with near-infinite speed and has smart pathfinding (somewhat like RP2 pneumatic tubes). Packets are measured in size (in EU/p) and volume (EU). (Size being the amount of energy it contains as it leaves a storage unit, volume being how much energy is left in each packet after inefficient cable usage).&lt;br /&gt;
&lt;br /&gt;
A HVT (or High Voltage Transformer) operates in two different ways.&lt;br /&gt;
&lt;br /&gt;
* If redstone power is &amp;#039;&amp;#039;&amp;#039;not&amp;#039;&amp;#039;&amp;#039; applied, it consumes 2048 EU in &amp;#039;&amp;#039;&amp;#039;any packet size&amp;#039;&amp;#039;&amp;#039; and converts them into up to four 512 EU/p. &amp;#039;&amp;#039;&amp;#039;All conversions are limited to one per tick. (Converting 2048 EU into 4x512 EU is considered one conversion.)&amp;#039;&amp;#039;&amp;#039;&lt;br /&gt;
* If redstone power is applied, it consumes 2048 EU in &amp;#039;&amp;#039;&amp;#039;any packet size&amp;#039;&amp;#039;&amp;#039; and converts them into one 2048 EU/p. &amp;#039;&amp;#039;&amp;#039;All conversions are limited to one per tick.&amp;#039;&amp;#039;&amp;#039;&lt;br /&gt;
== ==&lt;br /&gt;
{{Experimental}}&lt;br /&gt;
* In the Experimental version conversion direction and redstone behavior may also be controlled with the transformer GUI.&lt;br /&gt;
* Modes include: Fixed up/down and redstone controlled.&lt;br /&gt;
=== Converting to HV ===&lt;br /&gt;
In order to convert to HV, you must point the input cable (any &amp;quot;voltage&amp;quot;) to the 3-dotted side and then link any number of output cables from the 1-dotted side. Remember to use input cables that can withstand the packets you are sending in and [[HV Cable]] or [[Glass Fibre Cable]] for the output.&lt;br /&gt;
&lt;br /&gt;
=== Converting to EV ===&lt;br /&gt;
In order to convert to EV, you must &amp;#039;&amp;#039;&amp;#039;apply redstone power through a lever, a repeater or a redstone wire&amp;#039;&amp;#039;&amp;#039;, point the input cables (any &amp;quot;voltage&amp;quot;) to any 1-dotted side and then link the output cable from the 3-dotted side. Remember to use input cables that can withstand the packets you are sending in and [[HV Cable]] for the output.&lt;br /&gt;
&lt;br /&gt;
== Recipe ==&lt;br /&gt;
{{Experimental}}&lt;br /&gt;
{{Grid/Crafting Table&lt;br /&gt;
|B1=2xIns. Gold Cable&lt;br /&gt;
|A2=Electronic Circuit|B2=MV Transformer|C2=Advanced RE-Battery&lt;br /&gt;
|B3=2xIns. Gold Cable&lt;br /&gt;
|Output=HV Transformer&lt;br /&gt;
}}&lt;br /&gt;
&lt;br /&gt;
{{Energy&lt;br /&gt;
|Input= 2048 &amp;#039;&amp;#039;&amp;#039;EU&amp;#039;&amp;#039;&amp;#039;&lt;br /&gt;
|Output= Variable&lt;br /&gt;
* Up to 2048 EU in 512 EU/p when redstone is &amp;#039;&amp;#039;&amp;#039;not&amp;#039;&amp;#039;&amp;#039; applied.&lt;br /&gt;
* 1 packet of 2048 EU/p when redstone is applied.&lt;br /&gt;
|Storage=2048}}&lt;br /&gt;
&lt;br /&gt;
== Usage ==&lt;br /&gt;
{{Grid/Crafting Table&lt;br /&gt;
|B1=4xIns. HV Cable&lt;br /&gt;
|A2=Advanced Circuit|B2=HV Transformer|C2=Energy Crystal&lt;br /&gt;
|B3=4xIns. HV Cable&lt;br /&gt;
|Output=EV Transformer&lt;br /&gt;
}}&lt;br /&gt;
&lt;br /&gt;
== History (IC²) ==&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! IC²&lt;br /&gt;
! Minecraft&lt;br /&gt;
! Change&lt;br /&gt;
|-&lt;br /&gt;
| colspan=3 | Industrial Craft²&lt;br /&gt;
|-&lt;br /&gt;
! 2.0&lt;br /&gt;
| 1.6.4&lt;br /&gt;
| Before this version of IC², the [[HV Transformer]] was crafted using this recipe: &amp;lt;br/&amp;gt;&lt;br /&gt;
{{Grid/Crafting Table&lt;br /&gt;
|B1=4xIns. HV Cable&lt;br /&gt;
|A2=Electronic Circuit|B2=MV Transformer|C2=Energy Crystal&lt;br /&gt;
|B3=4xIns. HV Cable&lt;br /&gt;
|Output=HV Transformer&lt;br /&gt;
}}&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Other usages ==&lt;br /&gt;
Multiple HVT may be directly installed on a [[Nuclear Reactor]] if the reactor outputs more than 2048 EU/t as conventional wires ([[HV cables]]) cannot handle packet sizes over 2048 EU/p.&lt;br /&gt;
&lt;br /&gt;
{{Navigation}}&lt;br /&gt;
&lt;br /&gt;
[[Category:Wiring]]&lt;/div&gt;</summary>
		<author><name>Fern Silverthorn</name></author>
	</entry>
	<entry>
		<id>https://wiki.industrial-craft.net/index.php?title=Copper_Cable&amp;diff=15161</id>
		<title>Copper Cable</title>
		<link rel="alternate" type="text/html" href="https://wiki.industrial-craft.net/index.php?title=Copper_Cable&amp;diff=15161"/>
		<updated>2015-01-19T00:46:40Z</updated>

		<summary type="html">&lt;p&gt;Fern Silverthorn: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Copper cables are Tier 2, the 2nd-most common cable tier. They are  capable of handling &amp;#039;&amp;#039;&amp;#039;Medium Voltage&amp;#039;&amp;#039;&amp;#039; (up to 128 [[EU|EU-p]]), losing 1 EU every 5 blocks.&lt;br /&gt;
&lt;br /&gt;
They are also used in the creation of [[Electronic Circuit|Electronic Circuits]].&lt;br /&gt;
&lt;br /&gt;
== Crafting ==&lt;br /&gt;
&lt;br /&gt;
{|&lt;br /&gt;
|{{Grid/Crafting Table&lt;br /&gt;
|A2=Copper Plate|B2=Cutter&lt;br /&gt;
|Output=Copper Cable|OA=2&lt;br /&gt;
|Output-link=Copper Cable&lt;br /&gt;
}}&lt;br /&gt;
|{{Grid/Crafting Table&lt;br /&gt;
|A1=Rubber|B1=Copper Cable&lt;br /&gt;
|Output=Insulated Copper Cable&lt;br /&gt;
|Output-link=Insulated Copper Cable&lt;br /&gt;
}}&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
==Shocks==&lt;br /&gt;
(OLD)If you move too close to the uninsulated copper cable you may get an electric shock which does damage to the player so it&amp;#039;s best to insulate your cables.&lt;br /&gt;
* This feature seems to be disabled in Experimental versions of IC2 (Test made in 2_2.0.277-experimental)&lt;br /&gt;
&lt;br /&gt;
== [[Cable#Cable Efficiency|Cable Efficiency]] ==&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
!Cable type&lt;br /&gt;
!Max packet&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;left&amp;quot; | Uninsulated Copper Wire&lt;br /&gt;
| align=&amp;quot;right&amp;quot; | 128 EU-p&lt;br /&gt;
|-&lt;br /&gt;
| align=&amp;quot;left&amp;quot; | Insulated Copper Wire&lt;br /&gt;
| align=&amp;quot;right&amp;quot; | 128 EU-p&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
{{Navigation}}&lt;br /&gt;
&lt;br /&gt;
[[Category:Wiring]]&lt;/div&gt;</summary>
		<author><name>Fern Silverthorn</name></author>
	</entry>
	<entry>
		<id>https://wiki.industrial-craft.net/index.php?title=Gold_Cable&amp;diff=15160</id>
		<title>Gold Cable</title>
		<link rel="alternate" type="text/html" href="https://wiki.industrial-craft.net/index.php?title=Gold_Cable&amp;diff=15160"/>
		<updated>2015-01-19T00:45:30Z</updated>

		<summary type="html">&lt;p&gt;Fern Silverthorn: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{Experimental}}&lt;br /&gt;
Gold cables are Tier 3 [[Cable|cable]] type. They suffer higher distance-related energy losses than [[Copper Cable]]s, but are able to carry &amp;#039;&amp;#039;&amp;#039;High Voltage&amp;#039;&amp;#039;&amp;#039;, up to 512 [[EU|EU-p]]. Gold cables have 2 different levels of insulation, with the 2x insulation providing smaller energy losses per tile and less shock damage from high voltage.&lt;br /&gt;
&lt;br /&gt;
== Crafting ==&lt;br /&gt;
&lt;br /&gt;
{|&lt;br /&gt;
|{{Grid/Crafting Table&lt;br /&gt;
|A1=Gold Plate|B1=Cutter&lt;br /&gt;
|Output=Gold Cable|OA=4&lt;br /&gt;
}}&lt;br /&gt;
|&lt;br /&gt;
|}&lt;br /&gt;
{|&lt;br /&gt;
|{{Grid/Crafting Table&lt;br /&gt;
|A1=Rubber|B1=Rubber&lt;br /&gt;
|A2=Gold Cable&lt;br /&gt;
|Output=2xIns. Gold Cable&lt;br /&gt;
}}&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== [[Cable#Cable Efficiency|Cable Efficiency]] ==&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
! Cable type&lt;br /&gt;
! Max packet&lt;br /&gt;
|-&lt;br /&gt;
| Uninsulated Gold Cable&lt;br /&gt;
| 512 EU-p&lt;br /&gt;
|-&lt;br /&gt;
| Insulated Gold Cable&lt;br /&gt;
| 512 EU-p&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
{{Navigation}}&lt;br /&gt;
&lt;br /&gt;
[[Category:Wiring]]&lt;/div&gt;</summary>
		<author><name>Fern Silverthorn</name></author>
	</entry>
	<entry>
		<id>https://wiki.industrial-craft.net/index.php?title=Gold_Cable&amp;diff=15159</id>
		<title>Gold Cable</title>
		<link rel="alternate" type="text/html" href="https://wiki.industrial-craft.net/index.php?title=Gold_Cable&amp;diff=15159"/>
		<updated>2015-01-19T00:45:06Z</updated>

		<summary type="html">&lt;p&gt;Fern Silverthorn: Fixed typo&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{Experimental}}&lt;br /&gt;
Gold cables are Tier 2 [[Cable|cable]] type. They suffer higher distance-related energy losses than [[Copper Cable]]s, but are able to carry &amp;#039;&amp;#039;&amp;#039;High Voltage&amp;#039;&amp;#039;&amp;#039;, up to 512 [[EU|EU-p]]. Gold cables have 2 different levels of insulation, with the 2x insulation providing smaller energy losses per tile and less shock damage from high voltage.&lt;br /&gt;
&lt;br /&gt;
== Crafting ==&lt;br /&gt;
&lt;br /&gt;
{|&lt;br /&gt;
|{{Grid/Crafting Table&lt;br /&gt;
|A1=Gold Plate|B1=Cutter&lt;br /&gt;
|Output=Gold Cable|OA=4&lt;br /&gt;
}}&lt;br /&gt;
|&lt;br /&gt;
|}&lt;br /&gt;
{|&lt;br /&gt;
|{{Grid/Crafting Table&lt;br /&gt;
|A1=Rubber|B1=Rubber&lt;br /&gt;
|A2=Gold Cable&lt;br /&gt;
|Output=2xIns. Gold Cable&lt;br /&gt;
}}&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== [[Cable#Cable Efficiency|Cable Efficiency]] ==&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
! Cable type&lt;br /&gt;
! Max packet&lt;br /&gt;
|-&lt;br /&gt;
| Uninsulated Gold Cable&lt;br /&gt;
| 512 EU-p&lt;br /&gt;
|-&lt;br /&gt;
| Insulated Gold Cable&lt;br /&gt;
| 512 EU-p&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
{{Navigation}}&lt;br /&gt;
&lt;br /&gt;
[[Category:Wiring]]&lt;/div&gt;</summary>
		<author><name>Fern Silverthorn</name></author>
	</entry>
</feed>