<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://wiki.industrial-craft.net/api.php?action=feedcontributions&amp;feedformat=atom&amp;user=Eugene5348</id>
	<title>Industrial-Craft-Wiki - User contributions [en]</title>
	<link rel="self" type="application/atom+xml" href="https://wiki.industrial-craft.net/api.php?action=feedcontributions&amp;feedformat=atom&amp;user=Eugene5348"/>
	<link rel="alternate" type="text/html" href="https://wiki.industrial-craft.net/index.php?title=Special:Contributions/Eugene5348"/>
	<updated>2026-10-16T20:46:55Z</updated>
	<subtitle>User contributions</subtitle>
	<generator>MediaWiki 1.37.1</generator>
	<entry>
		<id>https://wiki.industrial-craft.net/index.php?title=Steam_Generator&amp;diff=18714</id>
		<title>Steam Generator</title>
		<link rel="alternate" type="text/html" href="https://wiki.industrial-craft.net/index.php?title=Steam_Generator&amp;diff=18714"/>
		<updated>2016-07-01T00:17:14Z</updated>

		<summary type="html">&lt;p&gt;Eugene5348: Super Heated Steam Is made at 221 bars, not 220&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;The &amp;#039;&amp;#039;&amp;#039;Steam Generator&amp;#039;&amp;#039;&amp;#039; requires [[Heat]] in order to boil [[Water]] into [[Steam]]. The most common use for the Steam is to be turned into power via the [[Kinetic Steam Generator]]. &lt;br /&gt;
&lt;br /&gt;
== Recipe ==&lt;br /&gt;
{{Grid/Crafting Table&lt;br /&gt;
|A1=Iron Item Casing|B1=Iron Item Casing|C1=Iron Item Casing&lt;br /&gt;
|A2=Iron Item Casing|B2=Copper Boiler|C2=Iron Item Casing&lt;br /&gt;
|A3=Iron Item Casing|B3=Heat Conductor|C3=Iron Item Casing&lt;br /&gt;
|Output=Steam Generator&lt;br /&gt;
}}&lt;br /&gt;
&lt;br /&gt;
== Usage ==&lt;br /&gt;
Boiling normal water causes the &amp;#039;&amp;#039;&amp;#039;Steam Generator&amp;#039;&amp;#039;&amp;#039; to calcify, as impurities build up inside. This can be fixed simply by breaking and replacing the Steam Generator. Calcification is measured by %, as has no effect until it is at 100%, at which point the Steam Generator will stop working.&lt;br /&gt;
&lt;br /&gt;
Using [[Distilled Water]] however, there are no impurities in the water, so it doesn&amp;#039;t increase the Steam Generator&amp;#039;s calcification, no matter how long it is used. Distilled Water is also produced from condensing [[Steam]] in either a [[Condenser]] or [[Kinetic Steam Generator]], meaning a closed cycle can be created. Water however would require a constant supply, and the produced Distilled Water to be dealt with separately. Water and Distilled Water cannot be used at the same time, but once a Steam Generator&amp;#039;s internal tank is empty, it can accept either, ignoring what it previously had in.&lt;br /&gt;
&lt;br /&gt;
The amount of Steam produced is solely down to what the controls in the GUI are set to. For every 1mb/t of (Distilled) Water that is put in, 100mb/t of Steam will be produced. If normal Steam is being produced, every 100mb/t of Steam also requires 100 [[hU]] in order to maintain the heating required. If the pressure is changed however, this value increases. The required heat increases logarithmically per bar of pressure. At 221+ bars, [[Superheated Steam]] is produced instead of normal Steam. The most efficient Superheated Steam setting is at 221 bars of pressure, as it takes 200 hU per 100 mb/t of Superheated Steam produced. It should be noted that the Superheated Steam is actually produced at 374&amp;lt;sup&amp;gt;o&amp;lt;/sup&amp;gt;C, and it is merely at 221 bars of pressure that this temperature is reached. There is a danger that above 500&amp;lt;sup&amp;gt;o&amp;lt;/sup&amp;gt;C the Steam Generator &amp;#039;&amp;#039;&amp;#039;will explode&amp;#039;&amp;#039;&amp;#039;, so the pressure should not be set above 250 bars, or [[Heat]] added without pumping/releasing (Distilled) Water in.&lt;br /&gt;
&lt;br /&gt;
If the required heat based off the Water input and pressure is either not provided the Steam Generator will fluctuate between producing Steam and just releasing (Distilled) Water. It is strongly recommended to set the pressure to 221 bars if Superheated Steam is desired else just leave it at 0 bars unless a specific amount of heat usage is needed for any reason.&lt;br /&gt;
&lt;br /&gt;
Visual &amp;#039;&amp;#039;&amp;#039;Steam explosions&amp;#039;&amp;#039;&amp;#039;, that don&amp;#039;t affect the environment but will hurt mobs and the player, do indicate a loss of (Distilled) Water.&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;Steam explosions&amp;#039;&amp;#039;&amp;#039; will happen, if not all steam that is produced by the Steam Generator is outputted into a valid tank (for example [[Fluid Distributor]]s, buildcraft pipes, etc). Keep in mind that the minimum output of 100 mb/t (2 buckets per second) is a very large amount of liquid so it is recommended to directly transfer the steam into a [[Kinetic Steam Generator]] as it will quickly fill up any tank.&lt;br /&gt;
The steam generator will eject steam automatically in every valid direction. The best way to prevent steam from blocking the distilled water supply is by using two [[Fluid Distributor]]s, one for inputting distilled water and one for outputting steam. The other four faces can then be used for heat supply.&lt;br /&gt;
&lt;br /&gt;
Any [[:Category:Heat Generator|Heat Generator]] can be used to heat a Steam Generator from any side (unlike most other [[Heat]] Machines that only have 1 input face), but only the [[Liquid Heat Exchanger]] and [[Electric Heat Generator]] provide up to 100 hU, that is more practical then several [[Fluid Heat Generator]]s that would be needed in order to reach 100 °C. Using an Electric Heat Generator &amp;#039;&amp;#039;&amp;#039;will always result in a net loss of energy&amp;#039;&amp;#039;&amp;#039;, even if all the produced (Superheated) Steam is turned into [[EU]] using the [[Kinetic Steam Generator]] connected to a [[Kinetic Generator]].&lt;br /&gt;
&amp;lt;!--Copyright IC2 Wiki ~Chocohead 2015--&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[Category:Steam]][[Category:Heat]][[Category:Heat Consumers]]&lt;/div&gt;</summary>
		<author><name>Eugene5348</name></author>
	</entry>
</feed>