Difference between revisions of "MV Transformer"

From Industrial-Craft-Wiki
Jump to navigation Jump to search
Line 1: Line 1:
{{Block
{{Block
|image=
|image=
|type=Wiring
|type=Transformer
|gravity=No
|gravity=No
|dirt=No
|dirt=No
Line 10: Line 10:
}}
}}


{{IC²}}
The MVT (MV Transformer) is used to turn '''High Voltage''' (512 [[EU#EU-Packet|EU-P]]) into '''Medium Voltage''' (128 EU-P) and back. This is useful for powering advanced machines and for medium-range energy transport.


The MV Transformer is used to turn '''High Power''' (512 [[EU#EU-Packet|EUP]]) into '''Medium Power''' (128 EUP) and back. This is useful for powering advanced machines and for medium-range energy transport.
By default, the MVT accepts 512 [[EU#EU-Packet|EU-P]] input and outputs 128 EUP. A 512 EUP or higher rated [[cable]] must be wired into the input face (the 3-dotted one) and 128 EUP or higher rated cable must be wired into the other faces.
 
By default, the Transformer accepts 512 [[EU#EU-Packet|EUP]] input and outputs 128 EUP. A 512 EUP or higher rated [[cable]] must be wired into the input face (the 3-dotted one) and 128 EUP or higher rated cable must be wired into the other faces.


A Redstone signal may be applied to reverse the conversion, thereby emitting 512 [[EU#EU-Packet|EUP]] from the output face (the 3-dotted one), and accepting 128 EUP or lower from the input faces. In reverse operation, 512 EUP or higher rated [[cable]] must be wired to the output face and any rate cable may be wired to the input faces.
A Redstone signal may be applied to reverse the conversion, thereby emitting 512 [[EU#EU-Packet|EUP]] from the output face (the 3-dotted one), and accepting 128 EUP or lower from the input faces. In reverse operation, 512 EUP or higher rated [[cable]] must be wired to the output face and any rate cable may be wired to the input faces.
Line 20: Line 18:
It can handle a maximum of one conversion per tick, limiting the maximum transfer to 512 [[EU#EU/t|EU/t]] in either mode.
It can handle a maximum of one conversion per tick, limiting the maximum transfer to 512 [[EU#EU/t|EU/t]] in either mode.


== Recipe ==
== Latest Recipe ==
 
{{Grid/Crafting Table
{{Grid/Crafting Table
|A1=|B1=2xIns. Gold Cable|C1=
|A1=|B1=2xIns. Gold Cable|C1=
Line 29: Line 26:
}}
}}


Note for wiki users. As for MFE units, do NOT replace "Golden cable" by "Copper cable" in the recipes. Check in game before changing. As the 1.97, recipes for MV tech are with golden cable, for balances issues.
<!-- Note for wiki users. As for MFE units, do NOT replace "Golden cable" by "Copper cable" in the recipes. Check in game before changing. As the 1.97, recipes for MV tech are with golden cable, for balances issues. The recipe of the old version has been transfered to the bottom. -->
 
 
'''Old Version'''
 
{{Grid/Crafting Table
|A1=|B1=Insulated Copper Cable|C1=
|A2=|B2=Machine|C2=
|A3=|B3=Insulated Copper Cable|C3=
|Output=MV Transformer
}}


== Usage ==
== Usage ==
Line 53: Line 40:
In order to convert from MV to HV, point the cable carrying MV from a [[MFE Transmitter]] or a [[LV Transformer]] to one of the one-dotted sides and then link a cable that can carry HV to the 3-dotted side. '''Do not forget to apply redstone''' to the MV Transformer.
In order to convert from MV to HV, point the cable carrying MV from a [[MFE Transmitter]] or a [[LV Transformer]] to one of the one-dotted sides and then link a cable that can carry HV to the 3-dotted side. '''Do not forget to apply redstone''' to the MV Transformer.


{{Energy|Input=128 or 512|Output=128 or 512|Storage=-}}
{{Energy
|Input=Variable
* Unlimited x max. 512 EU-p if not redstone'd
* Unlimited x max. 128 EU-p if redstone'd
|Output=Variable
* Unlimited x 128 EU-p if not redstone'd
* Unlimited x 512 EU-p if redstone'd
|Storage=512 EU}}
 
== History ==
{| class="wikitable"
! IC²
! Change
|-
| '''1.97'''
| Before this version, the recipe of the [[MV Transformer]] was: <br/>
{{Grid/Crafting Table
|B1=Insulated Copper Cable
|B2=Machine
|B3=Insulated Copper Cable
|Output=MV Transformer
}}
|-
|}


{{Navigation}}
{{Navigation}}

Revision as of 08:17, 13 January 2013

MV Transformer
Picture na.png
Grid MV Transformer.png
Properties
Type Transformer
Tool Grid Wrench.png




Stackable Yes (64)






Technical Details
UU Cost {{{uu_cost}}}
First appearance ?
ID IC2:{{{id}}}


The MVT (MV Transformer) is used to turn High Voltage (512 EU-P) into Medium Voltage (128 EU-P) and back. This is useful for powering advanced machines and for medium-range energy transport.

By default, the MVT accepts 512 EU-P input and outputs 128 EUP. A 512 EUP or higher rated cable must be wired into the input face (the 3-dotted one) and 128 EUP or higher rated cable must be wired into the other faces.

A Redstone signal may be applied to reverse the conversion, thereby emitting 512 EUP from the output face (the 3-dotted one), and accepting 128 EUP or lower from the input faces. In reverse operation, 512 EUP or higher rated cable must be wired to the output face and any rate cable may be wired to the input faces.

It can handle a maximum of one conversion per tick, limiting the maximum transfer to 512 EU/t in either mode.

Latest Recipe[edit]



Grid 2xIns. Gold Cable.png
Grid Machine.png
Grid 2xIns. Gold Cable.png



Grid MV Transformer.png



Usage[edit]

When using any Transformer, remember that the 3-dotted side means higher voltage and the 1-dotted sides mean lower voltage. You can change the direction the 3-dotted side is facing by right-clicking a 1-dotted face with a Wrench.

Converting to MV:[edit]

In order to convert from HV to MV, you must point the cable carrying HV from a HV Transformer or MFS Unit to the 3-dotted side and then link a cable that can carry MV to one of the sides with a single dot. Then that cable will be carrying MV that you can link to advanced machines, store in a MFE Transmitter or convert to LV with an LV Transformer.

Converting to HV:[edit]

In order to convert from MV to HV, point the cable carrying MV from a MFE Transmitter or a LV Transformer to one of the one-dotted sides and then link a cable that can carry HV to the 3-dotted side. Do not forget to apply redstone to the MV Transformer.

Energy[edit]

EU
Input Variable
  • Unlimited x max. 512 EU-p if not redstone'd
  • Unlimited x max. 128 EU-p if redstone'd
Output Variable
  • Unlimited x 128 EU-p if not redstone'd
  • Unlimited x 512 EU-p if redstone'd
Storage 512 EU

History[edit]

IC² Change
1.97 Before this version, the recipe of the MV Transformer was:



Grid Insulated Copper Cable.png
Grid Machine.png
Grid Insulated Copper Cable.png



Grid MV Transformer.png